Showing 1–20 of 29 results
5 DIGITAL MICROPROCESS METERwith 5 ALARMS / SIMULATION OUTPUT
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.1%F.S. ±1 digit(DC/Potentiometer/Resistor/PT-100/Load Cell) ±0.2%F.S. 1 digit (AC) Measuring AC,DC Voltage/AC,DC Current/Potentiometer/Resistor/PT-100/Load Cell) High brightness 0.8"LED display range:-19999~99999; decimal point selectable Max.Hold/Data Hold/Reset/2~4 Alarms(Hi or Lo)programmable/Analog output (15 bit resolution)/RS-485 communication optional (The above options can exist together) Alarm 5 can be set for ERROR mode to detect the error of the meter Individual simulation analog output to check the sensors High stability, non-flammable case (PC), high safety CE approval [/su_list]
5 DIGITAL MICROPROCESS RPM / LINEAR-SPEED / FREQUENCY METER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.03%F.S. Measuring AC Frequency/DC Pulse/Magnetic; Input frequency: 0.001Hz~100KHz High brightness 0.8"LED display range:0~99999; decimal point selectable Linear-Speed/RPM/Frequency selectable; Linear unit; M,Ft, Y/min selectable RPM pulse input programmable: 1~99999 2~4 alarms programmable(Hi or Lo)/Analog output(15 bit resolution)/RS-485 communication optional(The above option can exist together) High stability, non-flammable case (PC), high safety CE approval [/su_list]
3 1/2 DIGITAL PANEL METER (0.8″ LED)
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.1%F.S. ±1 digit(DC/Potentiometer /Resistor /PT-100/Load Cell) ±0.2%F.S. ±1 digit(AC). Measuring AC,DC Voltage/AC,DC Current/Potentiometer /Resistor /PT-100/Load Cell) High brightness 0.8"LED display range:-19999~99999; decimal point selectable High stability, non-flammable case (PC), high safety CE approval [/su_list]
ACTIVE/REACTIVE POWER(WATT/VAR) TRANSDUCER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.2% RO. Watt, Var packaged in one case Precision measurement even for unbalance system Precision measurement even for distorted wave High impulse & surge protection (5KV) The case can be mounted on a 35mm rail which complies with DIN 46277 [/su_list]
WATTHOUR / WATT TRANSDUCER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.25%F RO. Watthour, Watt packaged in one case Precision measurement even for distorted wave High impulse & surge protection (5KV) The case can be mounted on a 35mm rail which complies with DIN 46277 [/su_list]
WATTHOUR TRANSDUCER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.25% RO Precision measurement even for distorted wave Measuring both watthour & reverse watthour is available High impulse & surge protection (5KV) The case can be mounted on a 35mm rail which complies with DIN 46277 [/su_list]
ACTIVE POWER (WATT) TRANSDUCER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.2% RO Excellent long term stability(4~20mA, 750Ω) Precision measurement even for unbalance system Precision measurement even for distorted wave Measuring reverse watt is available High impulse & surge protection (5KV) The case can be mounted on a 35mm rail which complies with DIN 46277 [/su_list]
5 DIGITAL MICROPROCESS TEMPERATURE(THERMOCOUPLE) ISOLATED TRANSMITTER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.2% F.S. ±0.5°C (Cold junction compensation) Measuring Temperature (TC) sensors for K, J, E, R, S, B, T Measuring sensor disconnection High brightness 0.4" LED display range: -19999~99999; 1 decimal point selectable C° / F° unit selectable Surge test of AC 2000V / min between input / output / power High stability, non-flammable case (PC), high safety [/su_list]
5 DIGITAL MICROPROCESS RPM / LINEAR-SPEED /FREQUENCY ISOLATED TRANSMITTER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.03% F.S Measuring AC Frequency / DC Pulse / Magnetic; Input frequency: 0.001Hz~10KHz High brightness 0.4" LED display range: -19999~99999; decimal point selectable Line-Speed / RPM / Frequency selectable Line unit: M, Ft, Y/min selectable RPM pulse input programmable: 1~99999 Surge test of AC 2000V / min between input / output / powe High stability, non-flammable case (PC), high safety [/su_list]
5 DIGITAL MICROPROCESS SIGNALISOLATED TRANSMITTER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.1% F.S. (DC / Potentiometer / Resistor / PT-100 / Load Cell) ±0.2% F.S. (AC) Measuring AC, DC Voltage / AC, DC Current / Potentiometer / Resistor / PT-100 / Load Cell) High brightness 0.4" LED display range: -19999~99999; decimal point selectable Surge test of AC 2000V / min between input / output / power High stability, non-flammable case (PC), high safety [/su_list]
DUAL OUTPUT SIGNAL ISOLATED TRANSMITTER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.1% F.S. (DC / Potentiometer / Resistor / PT-100 / Load Cell) ±0.2% F.S. (AC) Measuring AC, DC Voltage / AC, DC Current / Potentiometer / Resistor / PT-100 / Load Cell) Surge test of AC 2000V / min between input / output / power High stability, non-flammable case (PC), high safety [/su_list]
ANALOG SIGNAL ISOLATED TRANSMITTER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.1% F.S. (DC / Potentiometer / Resistor / PT-100 / Load Cell) ±0.2% F.S. (AC) Measuring AC, DC Voltage / AC, DC Current / Potentiometer / Resistor / PT-100 / Load Cell) Surge test of AC 2000V / min between input / output / power High stability, non-flammable case (PC), high safety [/su_list]
VARHOURTRODUCER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.25%RO Precision measurement even for distorted wave High impulse & surge protection (5KV) The case can be mounted on a 35mm rail which complies with DIN 46277 [/su_list]
REACTIVE POWER (VAR) TRANSDUCER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.2%RO Excellent long term stability(4~20mA, 750Ω ) Precision measurement even for unbalance system Precision measurement even for distorted wave High impulse & surge protection (5KV) The case can be mounted on a 35mm rail which complies with DIN 46277 [/su_list]
POWER FACTOR, PHASE ANGLE TRANSDUCER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.02%PF(AP),±1°(AU) Excellent long term stability(4~20mA, 750Ω ) Precision measurement even for unbalance system Precision measurement even for distorted wave High impulse & surge protection (5KV) The case can be mounted on a 35mm rail which complies with DIN 46277 [/su_list]
6 DIGITAL MICROPROCESS COUNTERwith 1~4 ALARMS / ANALOG OUTPUT / RS-485
download pdf file [su_list icon="icon: circle"] High brightness 0.56" LED display:-199999~999999 Max. input frequency: 7KHz (1U2D / 1P2D); 1.5KHz (1A2B) Input pulse for pre-multiplcation & pre-division N/R/C relay output mode selectable 2~4 alarms output programmable (Hi or Lo)/Analog output(15 bit resolution)/RS-485 communication optional (The above option can exist together) Reset/Pause count by external control terminal available High stability, non-flammable case(PC),high safety CE approval [/su_list]
5 DIGITAL DUAL INPUT MICROPROCESS RPM /LINEAR-SPEED / FREQUENCY METER
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.03%F.S. Measuring AC Frequency/DC Pulse/Magnetic;Input frequency: 0.001Hz~100KHz High brightness 0.56" LED display:0~99999;decimal point selectable Linear-Speed/RPM /Frequency selectable Linear unit:M,Ft,Y/min selectable RPM pulse input programmable:1~99999 Dual input and display values selectablefor different parameters Dual input math function:B+A,B-A,B/A x100,(B/A-1)x100,B/(A+B)x100 High stability, non-flammable case(PC),high safety CE approval [/su_list]
10 DIGITAL MICROPROCESS Watt & Watt-Hr (Var & Var-Hr)Meter with ALARMS / ANALOG OUTPUT / RS-485
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.25%. Measuring AC Watt/Var /Watt-Hour /Var-Hour High brightness 0.4" LED;Watt(Var)display range: 0~19999;decimal point selectable Time parameters programmable(1 or 60 or 3600sec) Reset for Watt-Hour(Var-Hour) by external control input Individual alarm setting for Watt(Var) &Watt-Hour(Var-Hour) 2 Alarms for Watt(Var)/1 alarm for Watt-Hour(Var-Hour) /Pulse Output/Analog Output/(15 bit resolution) /RS-485 communication optional(The above options can exist together) High stability, non-flammable case(PC),high safety CE approval [/su_list]
5 DIGITAL MICROPROCESS TEMPERATURE (TC)METER with ALARMS / ANALOG OUTPUT / RS-485
download pdf file [su_list icon="icon: circle"] Accuracy: ±0.2%F.S. ±0.5°C(Cold junction compensation) Measuring Temperature(TC) sensors for K, J,E,R,S,B,T High brightness 0.56" LED display range:-19999~99999;1 decimal point selectable C°/ F° unit selectable 1 control output:ON /OFF or proportion programmable/2 Alarms output/Analog output (15 bit resolution)or RS-485 communication optional(The above options can exist together) High stability, non-flammable case(PC),high safety CE approval [/su_list]