Showing all 10 results

5 DIGITAL MICROPROCESS METERwith 5 ALARMS / SIMULATION OUTPUT

download pdf file [su_list icon="icon: circle"] Accuracy: ±0.1%F.S. ±1 digit(DC/Potentiometer/Resistor/PT-100/Load Cell) ±0.2%F.S. 1 digit (AC) Measuring AC,DC Voltage/AC,DC Current/Potentiometer/Resistor/PT-100/Load Cell) High brightness 0.8"LED display range:-19999~99999; decimal point selectable Max.Hold/Data Hold/Reset/2~4 Alarms(Hi or Lo)programmable/Analog output (15 bit resolution)/RS-485 communication optional (The above options can exist together) Alarm 5 can be set for ERROR mode to detect the error of the meter Individual simulation analog output to check the sensors High stability, non-flammable case (PC), high safety CE approval [/su_list]

6 DIGITAL MICROPROCESS COUNTERwith 1~4 ALARMS / ANALOG OUTPUT / RS-485

download pdf file [su_list icon="icon: circle"] High brightness 0.56" LED display:-199999~999999 Max. input frequency: 7KHz (1U2D / 1P2D); 1.5KHz (1A2B) Input pulse for pre-multiplcation & pre-division N/R/C relay output mode selectable 2~4 alarms output programmable (Hi or Lo)/Analog output(15 bit resolution)/RS-485 communication optional (The above option can exist together) Reset/Pause count by external control terminal available High stability, non-flammable case(PC),high safety CE approval [/su_list]

5 DIGITAL DUAL INPUT MICROPROCESS RPM /LINEAR-SPEED / FREQUENCY METER

download pdf file [su_list icon="icon: circle"] Accuracy: ±0.03%F.S. Measuring AC Frequency/DC Pulse/Magnetic;Input frequency: 0.001Hz~100KHz High brightness 0.56" LED display:0~99999;decimal point selectable Linear-Speed/RPM /Frequency selectable Linear unit:M,Ft,Y/min selectable RPM pulse input programmable:1~99999 Dual input and display values selectablefor different parameters Dual input math function:B+A,B-A,B/A x100,(B/A-1)x100,B/(A+B)x100 High stability, non-flammable case(PC),high safety CE approval [/su_list]

10 DIGITAL MICROPROCESS Watt & Watt-Hr (Var & Var-Hr)Meter with ALARMS / ANALOG OUTPUT / RS-485

download pdf file [su_list icon="icon: circle"] Accuracy: ±0.25%. Measuring AC Watt/Var /Watt-Hour /Var-Hour High brightness 0.4" LED;Watt(Var)display range: 0~19999;decimal point selectable Time parameters programmable(1 or 60 or 3600sec) Reset for Watt-Hour(Var-Hour) by external control input Individual alarm setting for Watt(Var) &Watt-Hour(Var-Hour) 2 Alarms for Watt(Var)/1 alarm for Watt-Hour(Var-Hour) /Pulse Output/Analog Output/(15 bit resolution) /RS-485 communication optional(The above options can exist together) High stability, non-flammable case(PC),high safety CE approval [/su_list]

5 DIGITAL MICROPROCESS TEMPERATURE (TC)METER with ALARMS / ANALOG OUTPUT / RS-485

download pdf file [su_list icon="icon: circle"] Accuracy: ±0.2%F.S. ±0.5°C(Cold junction compensation) Measuring Temperature(TC) sensors for K, J,E,R,S,B,T High brightness 0.56" LED display range:-19999~99999;1 decimal point selectable C°/ F° unit selectable 1 control output:ON /OFF or proportion programmable/2 Alarms output/Analog output (15 bit resolution)or RS-485 communication optional(The above options can exist together) High stability, non-flammable case(PC),high safety CE approval [/su_list]

10 DIGITAL MICROPROCESS TOTALIZER METERwith ALARMS / ANALOG OUTPUT / RS-485

download pdf file [su_list icon="icon: circle"] Accuracy: Analog input ±0.1%F.S. ±1 digit; Pulse input: ±0.003%F.S High brightness 0.4" LED;Rate of display range:0~99999 Rate/Total decimal point selectable Time parameters programmable(1 or 600r 3600sec) Total scale programmable (0.0001~9.9999) Pulse input range: 0.001~100KHz Reset for Total by external control input 2 Alarms for Rate/1 alarm for Total/Pulse output/Analog Output/(15 bit resolution)/RS-485 communication optional (The above options can exist together) High stability, non-flammable case (PC), high safety CE approval [/su_list]

5 DIGITAL MICROPROCESS METERwith 2~4 ALARMS / ANALOG OUTPUT / RS-485

download pdf file [su_list icon="icon: circle" class=" "] Accuracy: ±0.1%F.S. ±1 digit(DC/Potentiometer /Resistor /PT-100/Load Cell) ±0.2%F.S. ±1 digit(AC) Measuring AC,DC Voltage/AC,DC Current/Potentiometer /Resistor /PT-100/Load Cell) High brightness 0.8" LED display range:-19999~99999;decimal point selectable Display range programmable Max.Hold /Data Hold/Reset / 2~4 Alarms (Hi or Lo) programmable/Analog output (15 bit resolution) /RS-485 communication optional(The above options can exist together) High stability, non-flammable case(PC),high safety CE approval [/su_list]

5 DIGITAL MICRO PROCESS METER with 2 ALARMS

download pdf file [su_list icon="icon: circle" class=" "] Accuracy: ±0.1%F.S. ±1 digit(DC/Potentiometer /Resistor /PT-100) ±0.2%F.S. ±1 digit(AC) Measuring AC,DC Voltage/AC,DC Current/Potentiometer /Resistor /PT-100) High brightness 0.56" LED display range:-19999~99999;decimal point selectable Reset and 2 alarms (Normal Open Contact) setting(Hi or Lo)programmable High stability, non-flammable case(PC),high safety CE approval [/su_list]

5 DIGITAL MICROPROCESS METER

download pdf file [su_list icon="icon: circle" class=" "] Accuracy: ±0.1%F.S. ±1 digit(DC/Potentiometer /Resistor /PT-100) ±0.2%F.S. ±1 digit(AC) Measuring AC,DC Voltage/AC,DC Current/Potentiometer /Resistor /PT-100) High brightness 0.56" LED display range:-19999~99999;decimal point selectable Reset and 2 alarms (Normal Open Contact) setting(Hi or Lo)programmable High stability, non-flammable case(PC),high safety CE approval [/su_list]